Process notebook
PHA Process Record
Process Conditions Summary
Process statusStable
- Average setpoint
- 180.0°C
- Max deviation
- 2.0°C
- Zones monitored
- 13
Extruder Profile
- Model
- STEER 20mm L/D 45
- Type
- TSE
- L/D
- 45
- Screw Ø
- 20 mm
Temperature Profile
Temperature strategy
°C
Zone B1 reference
°C
Applied sequentially
Temperature control matrix
- Δ -2.0°C
B1
Actual 178.0°C
°C - Δ -2.0°C
B2
Actual 178.0°C
°C - Δ -2.0°C
B3
Actual 178.0°C
°C - Δ -2.0°C
B4
Actual 178.0°C
°C - Δ -2.0°C
B5
Actual 178.0°C
°C - Δ -2.0°C
B6
Actual 178.0°C
°C - Δ -2.0°C
B7
Actual 178.0°C
°C - Δ -2.0°C
B8
Actual 178.0°C
°C - Δ -2.0°C
B9
Actual 178.0°C
°C - Δ -2.0°C
B10
Actual 178.0°C
°C - Δ -2.0°C
B11
Actual 178.0°C
°C - Δ -2.0°C
DA
Actual 178.0°C
°C - Δ -2.0°C
Die
Actual 178.0°C
°C
| Zone | Set (°C) | Actual (°C) | Δ (°C) |
|---|---|---|---|
| B1 | °C | 178.0 | -2.0 |
| B2 | °C | 178.0 | -2.0 |
| B3 | °C | 178.0 | -2.0 |
| B4 | °C | 178.0 | -2.0 |
| B5 | °C | 178.0 | -2.0 |
| B6 | °C | 178.0 | -2.0 |
| B7 | °C | 178.0 | -2.0 |
| B8 | °C | 178.0 | -2.0 |
| B9 | °C | 178.0 | -2.0 |
| B10 | °C | 178.0 | -2.0 |
| B11 | °C | 178.0 | -2.0 |
| DA | °C | 178.0 | -2.0 |
| Die | °C | 178.0 | -2.0 |
Process Parameters
Process Parameters
rpm
Limit 1000 rpm
kg/h
Enter gravimetric feeder actual weight
%
Safe limit 100%
°C
Die thermocouple
Recent actions
- Zone B5 manually adjusted to 192°C
- Preset applied: PHA Start
- Feed rate set to 10 kg/h
Logs are stored locally for offline review and synced when connectivity is restored.
Check · Save options
Field memo
All inputs are auto-saved offline and sync is suggested on reconnection.
Review sections above before saving and correct any outliers immediately.